OECD TG 442C

OECD TG 442C defines in chemico test methods that evaluate the potential of chemical substances to react with skin proteins. The guide’s fundamental approach is to assess, in a laboratory setting, the protein reactivity that occurs during the initial stage of skin sensitization.

OECD TG 442C – In Vitro Skin Sensitization Test (Peptide Reactivity Assay – DPRA)

In the DPRA test, the interaction of the chemical substance with synthetic peptides containing cysteine and lysine is examined. The test substance is brought into contact with peptide solutions under specific conditions. After the reaction, the decrease in peptide concentration is measured using High-Performance Liquid Chromatography (HPLC).

The resulting peptide depletion rates indicate the chemical’s tendency to bind to proteins. These results are one of the key parameters used in assessing the potential for skin sensitization.

Why Is OECD TG 442C Conducted?

OECD TG 442C is conducted to help assess the risk of allergic skin sensitization by determining the capacity of chemical substances to react with skin proteins.

The primary objectives of the test are as follows:

  • To investigate the potential of chemical substances to form covalent bonds with proteins.
  • To evaluate the molecular interactions that occur during the initial stage of skin sensitization.
  • To support the determination of whether chemicals are skin sensitizers.
  • To provide additional data for identifying potent skin sensitizers.
  • To obtain results that can be used in safety assessments of cosmetic, chemical, and industrial products.
  • To utilize alternative testing methods that do not involve the use of animals.

OECD TG 442C: For Which Products Is It Performed?

OECD TG 442C can be used to evaluate chemical substances and mixtures that may come into contact with the skin and could cause allergic skin sensitization.

Examples of product and substance groups to which the test can be applied:

  • Cosmetic products and cosmetic raw materials
  • Perfumes and fragrance ingredients
  • Shampoos and hair care products
  • Skin care and personal care products
  • Detergents and cleaning chemicals
  • Disinfectant and biocide product ingredients
  • Paints and coating chemicals
  • Industrial chemical raw materials
  • Polymer and resin components
  • Chemical intermediates and various formulations

The applicability of the test to a specific substance must be determined by considering its chemical structure, solubility, reactivity, and the technical limitations of the test method used.

Please contact us for your analysis requests.

EnglishenEnglishEnglish