ISO 10993-17
ISO 10993-17 is a standard that governs the assessment of toxicological risks associated with chemical exposure that may arise from medical device components.
ISO 10993-17 – Toxicological Risk Assessment of Medical Device Components
Polymers, metals, coatings, adhesives, colorants, and other materials used in the manufacture of medical devices may contain various chemical components. Some of these components may come into contact with the body during the use of the device or may be released from the device, resulting in patient exposure.
The standard provides a systematic approach for identifying the potential health effects of these substances and assessing whether they pose a risk under realistic exposure conditions.
ISO 10993-17 specifically addresses the following topics:
- Determination of the toxicological properties of medical device components.
- Identification of potential harm that chemical substances may cause.
- Calculation of the amount of substance to which the patient may be exposed.
- Determination of the tolerable contact level or tolerable intake level.
- Assessment of the Toxicological Threshold of Concern (TTC) where appropriate.
- Examination of the relationship between exposure and toxicological effects.
- Calculation of the margin of safety (MoS).
Why Is ISO 10993-17 Performed?
The primary objective of ISO 10993-17 is to determine whether chemical exposure from medical devices is acceptable from a human health perspective.
In the biological evaluation of a device, it is not only the structure of the material that matters, but also the amount of chemical components that may migrate into the body during use and the toxicological properties of these components.
The evaluations conducted under this standard serve the following purposes:
- To identify the potential toxic effects of medical device components.
- To examine the health significance of chemical substances that may be released from the device.
- To calculate the patient’s daily or total exposure level.
- To assess acceptable exposure levels for chemical components.
- To investigate risks related to systemic toxicity and other relevant toxicological endpoints.
- To correlate the results of chemical characterization with the biological evaluation process.
- To prepare a toxicological risk assessment appropriate for the medical device’s conditions of use.
These studies provide important information throughout the process, ranging from the device’s design and material selection to the final biological safety assessment.
To Which Products Does ISO 10993-17 Apply?
ISO 10993-17 applies to medical devices that come into contact with the human body and for which exposure arising from their chemical components must be evaluated from a toxicological perspective.
Examples of product groups include:
- Surgical and orthopedic implants
- Catheters and intravascular medical devices
- Injection and infusion systems
- Surgical instruments and equipment
- Wound care products and dressing materials
- Dental materials and intraoral application devices
- Medical devices based on polymers, metals, and elastomers
- Medical products intended for long-term contact with the body
The need for evaluation depends on the body area the device comes into contact with, the duration of contact, the conditions of use, and the potential of the chemical components to cause exposure.