ISO 11737-2
ISO 11737-2 specifies the general requirements for sterility tests performed during the development and validation of sterilization processes for medical devices.
ISO 11737-2 – Sterility Tests in Sterilization Processes
In these tests, products exposed to the sterilizing agent at a lower level than during controlled and routine sterilization procedures are examined. The objective is to obtain microbiological data that will aid in defining and evaluating the sterilization process.
As part of the analysis, the entire product or a specific portion of it is examined using appropriate microbiological methods. Test results are recorded by assessing whether viable microorganisms have grown in the sample.
ISO 11737-2 does not cover pharmacopoeial sterility tests conducted for the routine release of products after sterilization. In this regard, the standard focuses on tests aimed at the development and validation of the sterilization process rather than direct final product sterility control.
Why Is ISO 11737-2 Performed?
Demonstrating the reliability of the sterilization process is a critical requirement for the microbiological safety of medical devices. Tests conducted under ISO 11737-2 support the microbiological evaluations necessary for defining and validating the sterilization process.
The primary objectives of the test are as follows:
- To obtain data for the development of the sterilization process.
- To support the validation of the sterilization process.
- To investigate the presence of viable microorganisms in products exposed to controlled sterilization conditions.
- To contribute to efforts to re-evaluate and maintain the sterilization process.
- To examine the suitability of the sterility test method for the product.
- To assist in the microbiological evaluation of the sterilization process.
These tests are particularly important when evaluating changes made to the sterilization process or during revalidation studies.
For Which Products Is ISO 11737-2 Applied?
ISO 11737-2 is used to evaluate healthcare products and medical devices that undergo a sterilization process and are intended to be supplied in a sterile state.
The main areas of application are as follows:
- Surgical instruments and surgical equipment
- Single-use medical devices
- Syringes and infusion systems
- Catheters and medical tubes
- Implants and implant components
- Wound care and dressing products
- Medical textile products
- Sterile healthcare products
- Medical device components subjected to the sterilization process
The applicability of the test is determined based on the product’s structure, the sterilization method, and the purpose of the validation study.