ISO 10993-6
ISO 10993-6 is an international standard that enables the evaluation of local biological effects that medical devices or the materials used in their manufacture may cause in surrounding tissues following implantation. As part of the biological evaluation process for medical devices, this standard defines the test requirements for examining changes that may occur in tissues following implantation.
The evaluation is based on investigating tissue reactions that may occur in the area where the test material is implanted. In this context, processes such as the material’s compatibility with surrounding tissue, tissue integration, degradation, or absorption by the body are examined.
Implantation studies conducted under ISO 10993-6 enable a comparative evaluation of the biological responses occurring in the tissues surrounding the material. In addition to macroscopic observations, the tests may also include microscopic and histopathological examinations of tissue samples.
Why Is ISO 10993-6 Conducted?
Medical devices implanted in the body interact directly with surrounding tissues throughout their useful life. As a result of this interaction, inflammation, foreign body reactions, tissue damage, or changes that may affect the material’s integration with surrounding tissues may occur at the implantation site.
The ISO 10993-6 test is conducted to examine these effects in advance and to contribute to the biological safety assessment of medical devices.
The primary objectives of the test are as follows:
- To identify biological reactions that may occur in surrounding tissues following implantation.
- To evaluate the tissue compatibility of medical device materials.
- To examine the process by which the material integrates with surrounding tissues.
- To investigate the effects of absorbable or degradable materials on tissues.
- To evaluate inflammatory and foreign body reactions that may occur at the implantation site.
- To obtain data for the biological risk analyses and safety dossiers of medical devices.
For Which Products Is ISO 10993-6 Performed?
ISO 10993-6 applies to medical devices intended for placement inside the body and requiring the evaluation of local tissue responses following implantation, as well as the materials used in their manufacture.
Product groups that can be evaluated under this scope include:
- Orthopedic implants: Bone plates, screws, joint prostheses, bone fixation systems, and orthopedic implant components.
- Dental implants: Dental implants, implant-supported components, bone grafts, and implant materials used in dentistry.
- Cardiovascular implants: Heart valves, vascular grafts, stents, and circulatory system devices implanted into the body.
- Surgical implants: Surgical sutures, surgical meshes, tissue-supporting materials, and other surgical products used for implantation.
- Biodegradable medical materials: Polymers, biological grafts, and tissue-supporting materials that break down or are absorbed by the body over time.
- Soft tissue implants: Implants, supportive materials, and prosthetic components used in tissue reconstruction.
- Biomaterials: Metal alloys, ceramics, polymers, porous structures, gels, and biological materials developed for implantation.
Testing requirements are determined by considering the product’s mode of contact with the body, the implantation site, duration of use, material properties, and biological risk assessment.
Please contact us with any questions you may have.