OECD TG 429

OECD TG 429 defines the Local Lymph Node Assay (LLNA) method, which is used to determine the potential of chemical substances to induce allergic sensitization following skin contact. The test helps assess the risk of developing allergic contact dermatitis by examining the immune response elicited by a chemical.

The method is based on measuring lymphocyte proliferation in the lymph nodes draining the application site following the application of the test substance to the skin. By evaluating this cell proliferation according to established criteria, information is obtained regarding the substance’s potential to induce skin sensitization.

OECD TG 429 is an in vivo test method conducted on mice. The updated version of the standard, effective in 2026, includes an evaluation option based on the direct counting of lymph node cells in addition to the radioactive labeling method.

Why Is OECD TG 429 Conducted?

Skin contact with a chemical does not always result in an immediate, visible reaction. However, some substances can cause the immune system to become sensitized to that compound. Subsequent exposure may then lead to allergic skin reactions.

OECD TG 429 is conducted to investigate this potential and to obtain data that can be used in the safety assessment of chemical substances.

The objectives of the test are as follows:

  • To investigate the potential of chemical substances to induce allergic skin sensitization.
  • To evaluate the cellular response of the immune system to chemical exposure.
  • To provide data for hazard classification and labeling of substances.
  • To evaluate the safety profile of chemical components present in product formulations.
  • To support chemical risk assessment and product safety studies.

OECD TG 429: Which Products Are Tested?

Various chemical products that may come into contact with the skin and pose a risk of allergic sensitization due to their ingredients can be evaluated under this test.

  • Cosmetic products: Skin care creams, lotions, hair dyes, makeup products, and raw materials used in cosmetic production.
  • Cleaning and detergent products: Household cleaning products, industrial detergents, surface cleaners, and cleaning chemicals.
  • Chemical formulations: Paints, varnishes, adhesives, resins, solvents, and various industrial chemical mixtures.
  • Biocidal products: Disinfectants, preservative chemicals, and active ingredients used in biocidal formulations.
  • Agricultural chemicals: Pesticides, plant protection products, and chemical preparations used in agricultural applications.
  • Medical device components: Polymers, coating materials, and chemical components used in devices that come into contact with the skin.
  • Pharmaceutical products: Topical medications, ointments, creams, and pharmaceutical raw materials that may come into contact with the skin.

The substance or product to be tested is determined based on its chemical structure, intended use, exposure conditions, and relevant regulatory requirements.

How Does the OECD TG 429 Testing Process Proceed?

Under OECD TG 429, the test substance is applied to the ear skin of test animals at specified concentrations. Following application, cellular activity in the relevant lymph nodes is examined. This evaluation helps determine the effect of chemical exposure on the immune system.

The following steps are followed during the testing process:

  • The properties of the test substance are examined to determine appropriate concentrations.
  • The test substance is applied to the skin according to the specified application schedule.
  • The lymph nodes draining the application site are prepared for evaluation.
  • Lymphocyte proliferation is measured using radioactive labeling or direct cell counting methods.
  • The data obtained is compared with control groups to assess the potential for skin sensitization.

The methods and evaluation criteria used in interpreting the results are taken into account. A threshold value of 3 is used for the Stimulation Index (SI) in the radioactive labeling method, while a threshold value of 1.5 is used in the method based on direct cell counting.

Please contact us for more details.

EnglishenEnglishEnglish