EN ISO 10993-23
EN ISO 10993-23 is a biological evaluation standard that enables the assessment of potential irritant effects that may result from the contact of medical devices and the materials used in them with human tissues. This standard, which is the 23rd part of the ISO 10993 series, is titled Biological Evaluation of Medical Devices – Tests for Irritation.
The primary objective of the standard is to examine the potential for irritation that medical devices, their components, or extracts derived from these materials may cause on the skin and related tissues. The evaluation process supports the biological safety and risk management approach conducted under ISO 10993-1.
EN ISO 10993-23 covers not only a specific test procedure but also pre-test evaluations, the selection of appropriate in vitro and in vivo methods, and the fundamental principles for interpreting results.
Basic Principle of the EN ISO 10993-23 Test
Under EN ISO 10993-23, irritation assessment is planned by considering the intended use of the medical device, the tissue it comes into contact with, the duration of contact, and the material properties. The sample to be tested may be the device itself, a specific part of the device, a component, or an extract prepared under appropriate conditions.
The testing process begins with a review of existing scientific and toxicological data. The material’s chemical composition, residues that may result from the manufacturing process, contact conditions, and previously obtained biological evaluation results are taken into account.
1. Pre-test evaluation
The intended use of the medical device, the contact area, and the exposure conditions are determined. The risk of irritation is assessed by reviewing the available literature, chemical characterization data, and previous biological test results. Where appropriate, in silico approaches and alternative test methods may also be considered.
2. In vitro irritation assessment
When methods with sufficient scientific validity for the appropriate and relevant area of use are available, cell- or tissue-based in vitro tests may be preferred. Reconstructed human epidermis (RhE) models may be used in the assessment of skin irritation.
These models help to investigate the irritation potential of the test substance or extract using tissue structures that mimic human skin. Cell viability and related biological responses are analyzed according to the evaluation criteria of the test method used.
3. In vivo irritation assessment
In cases where suitable in vitro methods are not available or the data obtained are insufficient for evaluation, in vivo methods may be considered in accordance with scientific and regulatory requirements. In these studies, the local reactions caused by the test sample in the appropriate contact area are examined.
Specific in vivo evaluation approaches for contact areas other than the skin are also described in the relevant annexes of the standard. The method to be used is determined based on the tissue with which the medical device comes into contact and the conditions of use.
In the standard’s approach, prioritizing suitable alternative methods that can replace animal testing and reducing the use of animals are of great importance.
Why Is the EN ISO 10993-23 Test Performed?
EN ISO 10993-23 is applied to identify the risks of local irritation that may arise from the contact of medical devices with the human body and to support the biological safety assessment.
The primary purposes of the test are as follows:
- Determination of skin irritation potential: Investigation of the irritating effects that medical devices or materials may cause as a result of contact with the skin.
- Assessment of biological safety: Investigating the compatibility of the device’s components and extracts with human tissues.
- Supporting medical device development processes: Providing data for the biological evaluation of new materials and product designs.
- Meeting regulatory requirements: Generating test data that can be used in the biological safety dossiers of medical devices.
- Evaluation of alternative test methods: Reducing the use of animals through in vitro methods where appropriate.
- Supporting risk management: Evaluating test results in conjunction with the device’s intended use, contact area, and duration of exposure.
- Improving product safety: Contributing to the identification of potential irritation risks in material selection and manufacturing processes.
EN ISO 10993-23 does not, on its own, evaluate all biological safety requirements of a medical device. Cytotoxicity, sensitization, systemic toxicity, and other biological effects may be examined separately under the relevant sections of the ISO 10993 series, depending on the device’s characteristics and risk assessment.
NANOTOX Laboratory addresses the work processes for evaluating the irritation potential of medical devices and their components under EN ISO 10993-23 in accordance with scientific requirements.
Organizations planning to conduct medical device irritation assessments under EN ISO 10993-23 may contact NANOTOX Laboratory for guidance on test approaches, sample preparation conditions, study design, and reporting procedures.