ISO 10993-18
ISO 10993-18 is an international standard published by the International Organization for Standardization (ISO), titled Biological Evaluation of Medical Devices – Part 18: Chemical Characterization of Medical Device Materials Within a Risk Management Process. It establishes a systematic framework for identifying and evaluating the chemical constituents of medical device materials as part of their overall biological safety assessment.
The standard provides guidance on how chemical characterization should be conducted and integrated into the risk management process, particularly in conjunction with ISO 14971. By generating reliable chemical data, ISO 10993-18 supports the evaluation of potential patient exposure to substances released from medical devices. It also contributes to the Weight-of-Evidence approach, helping manufacturers determine whether additional biological testing is necessary and supporting the reduction of unnecessary animal testing in line with the 3Rs principles.
Key Components of ISO 10993-18
The chemical characterization process under ISO 10993-18 involves several interconnected stages. These stages ensure that relevant chemical constituents are identified, quantified where possible, and evaluated in relation to potential biological risks.
1. Collection of Material and Medical Device Information
The first stage involves gathering comprehensive information about the medical device and its constituent materials. This information provides the foundation for selecting appropriate extraction and analytical strategies.
- Relevant documentation includes:
- Raw materials, material composition and formulation details
- Manufacturing processes, including molding, extrusion, coating and other production techniques
- Sterilization methods and packaging materials
- Safety Data Sheets (SDS), supplier certificates and available compositional information
- Previous chemical characterization studies and relevant scientific literature
- Historical data concerning material processing and potential chemical changes
2. Extraction Studies
Extraction studies are performed to identify substances that may be released from medical device materials. These studies are generally designed in accordance with ISO 10993-12, considering the intended clinical application and relevant exposure conditions.
Three principal extraction approaches are commonly considered:
- Simulated-Use Extraction: Conducted under conditions designed to represent the intended clinical application, taking into account factors such as temperature, extraction medium and contact duration.
- Exaggerated Extraction: Uses more aggressive extraction conditions than those expected during clinical use to identify a broader range of potentially extractable substances.
- Exhaustive Extraction: Aims to recover the maximum possible amount of extractable chemical constituents, providing a comprehensive profile of the material’s chemical composition.
The selection of extraction conditions depends on the medical device’s intended use, material characteristics and the objectives of the chemical characterization study.
3. Analytical Characterization
Following extraction, appropriate analytical techniques are selected to identify and quantify chemical constituents in the resulting extracts. The selection depends on the physicochemical properties of the substances and the expected concentration ranges.
Commonly used analytical techniques include:
- Volatile and Semi-Volatile Organic Compounds: GC-MS, GC-FID and Headspace GC-MS
- Non-Volatile Organic Compounds: HPLC-UV/DAD, LC-MS, LC-MS/MS and LC-HRMS
- Elemental and Metal Analysis: ICP-MS and ICP-OES
- Ionic Compounds: Ion Chromatography (IC)
- Total Organic Carbon (TOC): Assessment of the overall organic carbon content
- Structural Identification: FTIR and NMR spectroscopy
Combining complementary analytical techniques helps establish a more comprehensive chemical profile and improves the identification of potentially relevant substances.
4. Analytical Evaluation Threshold (AET)
The Analytical Evaluation Threshold (AET) is an important concept in ISO 10993-18. It establishes a reporting threshold used to determine which detected chemical constituents require further identification and toxicological assessment.
The AET is calculated by considering factors such as the intended clinical exposure, analytical sample preparation, extraction conditions and relevant toxicological considerations. Depending on the assessment strategy, the Threshold of Toxicological Concern (TTC) approach or substance-specific toxicological data may be used to support the evaluation.
Substances detected above the AET generally require further investigation, including identification and, where possible, quantification. Findings below the AET should also be considered in accordance with the study’s analytical strategy and applicable assessment requirements.
5. Evaluation of Leachables
An important distinction in chemical characterization is the difference between extractables and leachables.
- Extractables: Chemical substances that can be released from a material under defined laboratory extraction conditions.
- Leachables: Substances that migrate from a medical device or its components under actual or simulated conditions of clinical use.
While extractables studies provide information about the potential chemical constituents of a material, leachables assessments focus on substances to which patients may actually be exposed during device use.
Leachables evaluation may involve simulated-use studies, clinical-use information and exposure-based assessments, depending on the characteristics and intended application of the medical device.
6. Toxicological Risk Assessment
Identified chemical constituents are evaluated to determine their potential toxicological significance and associated patient exposure risks.
The assessment may incorporate:
- Available toxicological and scientific literature
- Substance-specific toxicological reference values
- Threshold of Toxicological Concern (TTC) methodology, where applicable
- Read-Across approaches
- Structure-Activity Relationship (SAR) and Quantitative Structure-Activity Relationship (QSAR) assessments
- Exposure estimation and dose calculations
- Evaluation of uncertainties associated with unidentified or partially identified substances
The resulting toxicological assessment contributes to the overall biological evaluation of the medical device in accordance with ISO 10993-1.
7. Relationship Between Chemical Characterization and Biological Testing
Chemical characterization provides valuable information that can support decisions regarding the need, extent and selection of biological tests.
When scientifically justified, chemical data may help reduce or avoid certain additional biological tests by providing sufficient evidence for specific biological safety endpoints. However, chemical characterization does not automatically replace biological testing.
Endpoints such as local tissue effects, sensitization, genotoxicity and implantation require appropriate consideration within the overall biological evaluation strategy. The need for additional testing should be determined through a comprehensive assessment of chemical data, existing biological evidence and the intended clinical use of the device.
Why Is ISO 10993-18 Testing Performed?
ISO 10993-18 chemical characterization is performed to support the biological safety evaluation of medical devices and address potential chemical risks throughout their lifecycle.
Its main applications and objectives include:
- Supporting Biological Safety Assessments: Identifying and characterizing chemical substances that may be released from medical device materials and contribute to patient exposure.
- Reducing Animal Testing: Supporting the 3Rs principles by using chemical characterization data within a Weight-of-Evidence approach to avoid unnecessary animal studies where scientifically justified.
- Integrating Chemical Risk Management: Providing relevant chemical information for identifying, evaluating and controlling potential risks in accordance with ISO 14971.
- Supporting MDR Compliance: Generating chemical characterization data required for biological safety assessments under the European Medical Device Regulation (EU) 2017/745.
- Material and Process Development: Identifying potentially hazardous chemical constituents, impurities and manufacturing residues during product development.
- Supply Chain Evaluation: Assessing raw material quality and determining the potential impact of changes in suppliers or material formulations.
- Sterilization Impact Assessment: Investigating chemical residues and degradation products that may arise from sterilization processes such as ethylene oxide (EO), gamma radiation and electron beam treatment.
- Packaging Interaction Studies: Evaluating potential chemical migration from packaging materials into medical devices.
- Regulatory Submission Support: Providing essential chemical characterization information for biocompatibility documentation submitted to regulatory authorities, including the FDA and European regulatory bodies.
- Weight-of-Evidence Evaluation: Combining chemical characterization results with relevant biological testing and clinical information to establish a comprehensive understanding of medical device safety.
It is important to emphasize that ISO 10993-18 alone does not establish the complete biological safety profile of a medical device. Chemical characterization results must be interpreted alongside relevant biological tests, clinical information, exposure assessments and the overall risk management process. Additional testing may be necessary depending on the device’s materials, intended use and potential patient exposure.
Through our laboratory infrastructure and quality management practices, we aim to provide reliable analytical data that can contribute to chemical risk assessment and regulatory documentation.
For your ISO 10993-18 chemical characterization requirements, NANOTOX Laboratory can support the evaluation process through a scientific approach covering material information, extraction strategies, analytical method selection, chemical identification and quantification, AET-related assessments and reporting.